FTE-1600S standard electromagnetic flowmeter using the principle of electromagnetic induction, according to the conductive fluid through the external magnetic field induced EMF to measure the conductive fluid flow of an instrument, widely used in clean water, sewage, corrosive, the flow rate of toxic and other conductive liquid or liquid-solid two-phase medium, no blocking moving parts in the pipe, almost no pressure loss, straight pipe section requirements are lower, showing the cumulative flow rate, instantaneous flow rate, flow rate percentage, etc. , it has been widely used in chemical industry, environmental protection, metallurgy, medicine, paper, water supply and drainage and other industrial technology and management departments.
Product Selection
Expert Q&A
5% off for new customers
Specification
Performance Features
FTE-1600S electromagnetic flowmeter based on the principle of Faraday's law of induction to measure the volume flow of conductive liquid instruments, is a combination of fluid mechanics and electromagnetic products. We updated the FTE-1600 electromagnetic flowmeter. Both in appearance and assembly mode, or in the internal structure, have made a new breakthrough: angular appearance, magnetic field distribution better rationalized structure. At the same time, the zinc spraying process is introduced, which can protect the surface of electromagnetic flowmeter for a long time even in harsh environment.
Low flow rate high precision, lower limit up to 0.03 m/s;
The outer shell of the sensor is all made of precision aluminum mould, with beautiful products, strong consistency in appearance, close fitting, no welding as a whole, fast loading and unloading, convenient maintenance;
Thickened type lining, arc surface electrode, with good corrosion resistance and wear resistance, the ability to adapt to mixed media is stronger;
‖ no flow-blocking parts in the measuring pipe, no pressure loss, low requirements for straight pipe section. Has the unique adaptability to the size measurement;
The use of 16-bit embedded microprocessor, fast operation speed, high accuracy, programmable frequency low-frequency rectangular wave magnetic, improve the stability of flow measurement, low power consumption;
The adoption of SMD devices and surface mount (SMT) technology, circuit reliability is high;
At the scene, the measuring range can be modified on line according to the actual needs of the users, so as to better match with the acquisition terminal;
The measurement results are independent of the physical parameters such as fluid pressure, temperature, density, viscosity, etc.
‖ digital communication signal outputs (optional) including RS485, RS232, Hart and Modbus, Profibus-DP;
With self-examination and self-diagnosis self-diagnosis and alarm function;
Ultra-low EMI switching power supply, suitable for wide range of power supply voltage changes, anti-EMI performance.
Technical parameters
Implementation standards   Electromagnetic flowmeter (JB/T 9248-2015)
Suitable medium Acid, alkali, salt solution, water, sewage, corrosive liquid and mud, pulp, pulp and other conductive liquid, solid-liquid two-phase

Nominal Meridians (mm)

Special specifications can be customized 

 Tube type teflon lining: DN15-DN2000
 Pipeline rubber lining: DN65-DN2000
 Tubular F46 lining: DN4-DN600
Direction of flow   Positive, negative, net flow
Range ratio   150:1
Repeatability error   ± 0.1% of the measured value
Accuracy Level   0.5,1.0
The temperature of the measured medium   Conventional rubber lining: -20 ~ + 60 ° C
 High temperature rubber lining: -20 ~ + 90 ° C
 Polytetrafluoroethylene lining: -30 â ° â ° + 120 â ° C
 High temperature tetrafluorin linings: -20 ~ + 160 ° C
Rated working pressure (high pressure can be customized)   DN15ー DN25≤4.0 MPa
 DN32ー DN300≤1.6 MPa
 DN350ー DN800≤1.0 MPa
 DN800ー DN2000≤0.6 MPa
Velocity Range   0.1-15m/s
Electrical conductivity range   The conductivity of the measured fluid is more than 20 μs/cm
Signal output   4-20mA (load resistance 0-750ω) , pulse/frequency
Communication output   RS485, Modbus protocol, GPRS output
Power supply   220VAC, tolerance 15% or 24VDC, ripple ≤5%
Straight pipe section length is required   Upstream ≥5 dn, downstream ≥3 dn, installation conditions affect the requirements of straight pipe section
Connection mode   Flanged connection is adopted between flowmeter and piping. Flanged connection conforms to international standard: GB/T9119 -2000
Protection level   IP67
Ambient temperature   -25~+60℃
Relative humidity   5%~95%
Consumption of total power   Less than 7.5 W
Not sure which Instruments and sensors to choose?
No worries! We understand that getting the perfect Instruments and sensors that meets your needs can be pretty tricky. Our dedicated Engineering experts are here to support you with:
Expert advice on choosing the best material and structure to meet your needs
Professional guidance from engineers on building the best Sensors and Instruments experience
Anytime support with full-cycle project management and proactive updates
Get a product quote
Fill in our quote request form and we will reply to your message as soon as possible! Or send us an email at: info@doweston.com